CVE-2026-82948

RF Replay of control commands

Published Nov 19, 2026 CVSS 4.0 · 7.1 High EPSS n/a KEV · Not listed
Description
The Guardian 2 alarm unit lacks a mechanism to
authenticate control commands sent over 433.92 MHz, which allows an attacker to
replay the static commands to impersonate activity.  The attacker can also disarm or arm the
system at will if a Nexsmart keypad (product link) is in use, thus compromising
the functionality of the alarm system completely.

Remediation

Vendor Solution

Nexsmart reported suspending sales and described a phase-out of the current Guardian models. If you own an affected system and are concerned, contact Nexsmart through its official support channels and ask about any current remediation guidance.

Tracking

Sign in to view the affected projects.

Advisories

No advisories available
History
Type Values Removed Values Added
Description The Guardian 2 alarm unit lacks a mechanism to authenticate control commands sent over 433.92 MHz, which allows an attacker to replay the static commands to impersonate activity.  The attacker can also disarm or arm the system at will if a Nexsmart keypad (product link) is in use, thus compromising the functionality of the alarm system completely.
Title RF Replay of control commands
Weaknesses CWE-294
References
Metrics cvssV4_0

{'score': 7.1, 'vector': 'CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N'}

Subscriptions

No data.

Weaknesses

Sources

Status
PUBLISHED
Assigner
ENISA
Published
Updated
Nov 19, 2026, 10:30 AM
Reserved
Aug 31, 2026, 12:26 PM

No data.