{"affected": [{"affectedData": [{"defaultStatus": "unknown", "product": "Mendix Runtime V10", "vendor": "Siemens", "versions": [{"lessThan": "V10.21.0", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "Mendix Runtime V10.12", "vendor": "Siemens", "versions": [{"lessThan": "V10.12.16", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "Mendix Runtime V10.18", "vendor": "Siemens", "versions": [{"lessThan": "V10.18.5", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "Mendix Runtime V10.6", "vendor": "Siemens", "versions": [{"lessThan": "V10.6.22", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "Mendix Runtime V8", "vendor": "Siemens", "versions": [{"lessThan": "V8.18.35", "status": "affected", "version": "0", "versionType": "custom"}]}, {"defaultStatus": "unknown", "product": "Mendix Runtime V9", "vendor": "Siemens", "versions": [{"lessThan": "V9.24.34", "status": "affected", "version": "0", "versionType": "custom"}]}], "source": "productcert@siemens.com"}], "cveTags": [], "descriptions": [{"lang": "en", "value": "A vulnerability has been identified in Mendix Runtime V10 (All versions < V10.21.0), Mendix Runtime V10.12 (All versions < V10.12.16), Mendix Runtime V10.18 (All versions < V10.18.5), Mendix Runtime V10.6 (All versions < V10.6.22), Mendix Runtime V8 (All versions < V8.18.35), Mendix Runtime V9 (All versions < V9.24.34). Affected applications allow for entity enumeration due to distinguishable responses in certain client actions. This could allow an unauthenticated remote attacker to list all valid entities and attribute names of a Mendix Runtime-based application."}, {"lang": "es", "value": "Se ha identificado una vulnerabilidad en Mendix Runtime V10 (todas las versiones anteriores a la V10.21.0), Mendix Runtime V10.12 (todas las versiones), Mendix Runtime V10.18 (todas las versiones), Mendix Runtime V10.6 (todas las versiones), Mendix Runtime V8 (todas las versiones) y Mendix Runtime V9 (todas las versiones anteriores a la V9.24.34). Las aplicaciones afectadas permiten la enumeraci\u00f3n de entidades debido a respuestas distinguibles en ciertas acciones del cliente. Esto podr\u00eda permitir que un atacante remoto no autenticado liste todas las entidades y nombres de atributos v\u00e1lidos de una aplicaci\u00f3n basada en Mendix Runtime."}], "id": "CVE-2025-30280", "lastModified": "2026-06-17T09:08:27.360", "metrics": {"cvssMetricV31": [{"cvssData": {"attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 5.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "LOW", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N", "version": "3.1"}, "exploitabilityScore": 3.9, "impactScore": 1.4, "source": "productcert@siemens.com", "type": "Secondary"}], "cvssMetricV40": [{"cvssData": {"Automatable": "NOT_DEFINED", "Recovery": "NOT_DEFINED", "Safety": "NOT_DEFINED", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "availabilityRequirement": "NOT_DEFINED", "baseScore": 6.9, "baseSeverity": "MEDIUM", "confidentialityRequirement": "NOT_DEFINED", "exploitMaturity": "NOT_DEFINED", "integrityRequirement": "NOT_DEFINED", "modifiedAttackComplexity": "NOT_DEFINED", "modifiedAttackRequirements": "NOT_DEFINED", "modifiedAttackVector": "NOT_DEFINED", "modifiedPrivilegesRequired": "NOT_DEFINED", "modifiedSubAvailabilityImpact": "NOT_DEFINED", "modifiedSubConfidentialityImpact": "NOT_DEFINED", "modifiedSubIntegrityImpact": "NOT_DEFINED", "modifiedUserInteraction": "NOT_DEFINED", "modifiedVulnAvailabilityImpact": "NOT_DEFINED", "modifiedVulnConfidentialityImpact": "NOT_DEFINED", "modifiedVulnIntegrityImpact": "NOT_DEFINED", "privilegesRequired": "NONE", "providerUrgency": "NOT_DEFINED", "subAvailabilityImpact": "NONE", "subConfidentialityImpact": "NONE", "subIntegrityImpact": "NONE", "userInteraction": "NONE", "valueDensity": "NOT_DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "version": "4.0", "vulnAvailabilityImpact": "NONE", "vulnConfidentialityImpact": "LOW", "vulnIntegrityImpact": "NONE", "vulnerabilityResponseEffort": "NOT_DEFINED"}, "source": "productcert@siemens.com", "type": "Secondary"}], "ssvcV203": [{"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "ssvcData": {"id": "CVE-2025-30280", "options": [{"exploitation": "none"}, {"automatable": "yes"}, {"technicalImpact": "partial"}], "role": "CISA Coordinator", "timestamp": "2025-04-08T13:10:20.606472Z", "version": "2.0.3"}}]}, "published": "2025-04-08T09:15:27.793", "references": [{"source": "productcert@siemens.com", "url": "https://cert-portal.siemens.com/productcert/html/ssa-874353.html"}], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Deferred", "weaknesses": [{"description": [{"lang": "en", "value": "CWE-204"}], "source": "productcert@siemens.com", "type": "Secondary"}]}