Search vulnerabilities

Results 1,968

Export CSV
CVE-2019-9975

DASAN H660RM devices with firmware 1.03-0022 use a hard-coded key for logs encryption. Data stored using this key can be decrypted by anyone able to access this key.

CVSS 3.0 · 7.5 High EPSS 1.3% KEV · Not listed
Vendors
CVE-2019-9533

The root password of the Cobham EXPLORER 710 is the same for all versions of firmware up to and including v1.08

The root password of the Cobham EXPLORER 710 is the same for all versions of firmware up to and including v1.08. This could allow an attacker to reverse-engineer the password from available versions to gain authenticated access to the device.

CVSS 3.1 · 9.8 Critical EPSS 1.5% KEV · Not listed
Vendors
CVE-2019-9493

MyCar Controls uses hard-coded credentials

The MyCar Controls of AutoMobility Distribution Inc., mobile application contains hard-coded admin credentials. A remote unauthenticated attacker may be able to send commands to and retrieve data from a target MyCar unit. This may allow the attacker to learn the location of a target, or gain unauthorized physical access to a vehicle. This issue affects AutoMobility MyCar versions prior to 3.4.24 on iOS and versions prior to 4.1.2 on Android. This issue has additionally been fixed in Carlink, Link, Visions MyCar, and MyCar Kia.

CVSS 3.1 · 6.5 Medium EPSS 3.6% KEV · Not listed
Vendors
Products
CVE-2019-9229

An issue was discovered on AudioCodes Mediant 500L-MSBR, 500-MBSR, M800B-MSBR and 800C-MSBR devices with firmware versions F7.20A to F7.20A.251. An internal interface exposed to the link-local address 169.254.254.253 allows attackers in the local network to access multiple quagga VTYs. Attackers can authenticate with the default 1234 password that cannot be changed, and can execute malicious and unauthorized actions.

CVSS 3.0 · 8.8 High EPSS < 1% KEV · Not listed
Vendors
CVE-2019-9160

WAC on the Sangfor Sundray WLAN Controller version 3.7.4.2 and earlier has a backdoor account allowing a remote attacker to login to the system via SSH (on TCP port 22345) and escalate to root (because the password for root is the WebUI admin password concatenated with a static string).

CVSS 3.0 · 9.8 Critical EPSS 3.2% KEV · Not listed
Vendors
CVE-2019-8950

The backdoor account dnsekakf2$$ in /bin/login on DASAN H665 devices with firmware 1.46p1-0028 allows an attacker to login to the admin account via TELNET.

CVSS 3.0 · 9.8 Critical EPSS 2.9% KEV · Not listed
Vendors
Products
CVE-2019-8352

By default, BMC PATROL Agent through 11.3.01 uses a static encryption key for encrypting/decrypting user credentials sent over the network to managed PATROL Agent services. If an attacker were able to capture this network traffic, they could decrypt these credentials and use them to execute code or escalate privileges on the network.

CVSS 3.1 · 9.8 Critical EPSS 6.3% KEV · Not listed
Vendors
Bmc
Products
CVE-2019-7672

Prima Systems FlexAir, Versions 2.3.38 and prior. The flash version of the web interface contains a hard-coded username and password, which may allow an authenticated attacker to escalate privileges.

CVSS 3.1 · 8.8 High EPSS 2.4% KEV · Not listed
Vendors
Products
CVE-2019-7594

Metasys use of hardcoded RC2 key

Metasys® ADS/ADX servers and NAE/NIE/NCE engines prior to 9.0 make use of a hardcoded RC2 key for certain encryption operations involving the Site Management Portal (SMP).

CVSS 3.0 · 6.8 Medium EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2019-7593

Metasys use of shared RSA key pairs

Metasys® ADS/ADX servers and NAE/NIE/NCE engines prior to 9.0 make use of a shared RSA key pair for certain encryption operations involving the Site Management Portal (SMP).

CVSS 3.0 · 6.8 Medium EPSS < 1% KEV · Not listed
Vendors
Products
CVE-2019-7225

The ABB HMI components implement hidden administrative accounts that are used during the provisioning phase of the HMI interface. These credentials allow the provisioning tool "Panel Builder 600" to flash a new interface and Tags (MODBUS coils) mapping to the HMI. These credentials are the idal123 password for the IdalMaster account, and the exor password for the exor account. These credentials are used over both HTTP(S) and FTP. There is no option to disable or change these undocumented credentials. An attacker can use these credentials to login to ABB HMI to read/write HMI configuration files and also to reset the device. This affects ABB CP635 HMI, CP600 HMIClient, Panel Builder 600, IDAL FTP server, IDAL HTTP server, and multiple other HMI components.

CVSS 3.1 · 8.8 High EPSS 2.9% KEV · Not listed
Vendors
Abb
Products
CVE-2019-7212

SmarterTools SmarterMail 16.x before build 6985 has hardcoded secret keys. An unauthenticated attacker could access other users’ emails and file attachments. It was also possible to interact with mailing lists.

CVSS 3.0 · 8.2 High EPSS 1.0% KEV · Not listed
Vendors
Products
CVE-2019-6859

A CWE-798: Use of Hardcoded Credentials vulnerability exists in Modicon Controllers (All versions of the following CPUs and Communication Module product references listed in the Security Notifications), which could cause the disclosure of FTP hardcoded credentials when using the Web server of the controller on an unsecure network.

CVSS 3.1 · 7.5 High EPSS 1.2% KEV · Not listed
CVE-2019-6725

The rpWLANRedirect.asp ASP page is accessible without authentication on ZyXEL P-660HN-T1 V2 (2.00(AAKK.3)) devices. After accessing the page, the admin user's password can be obtained by viewing the HTML source code, and the interface of the modem can be accessed as admin.

CVSS 3.0 · 9.8 Critical EPSS 1.8% KEV · Not listed
Vendors
CVE-2019-6698

Use of Hard-coded Credentials vulnerability in FortiRecorder all versions below 2.7.4 may allow an unauthenticated attacker with knowledge of the aforementioned credentials and network access to FortiCameras to take control of those, provided they are managed by a FortiRecorder device.

CVSS 3.1 · 9.8 Critical EPSS 1.5% KEV · Not listed
Vendors
CVE-2019-6572

A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The affected device offered SNMP read and write capacities with a publicly know hardcoded community string. The security vulnerability could be exploited by an attacker with network access to the affected device. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.

CVSS 3.1 · 9.1 Critical EPSS 2.7% KEV · Not listed
Vendors