An issue was discovered in phpMyAdmin. Username matching for the allow/deny rules may result in wrong matches and detection of the username in the rule due to non-constant execution time. All 4.6.x versions (prior to 4.6.5), 4.4.x versions (prior to 4.4.15.9), and 4.0.x versions (prior to 4.0.10.18) are affected.
Search vulnerabilities
An issue was discovered in phpMyAdmin. With a crafted request parameter value it is possible to bypass the logout timeout. All 4.6.x versions (prior to 4.6.5), and 4.4.x versions (prior to 4.4.15.9) are affected.
An issue was discovered in phpMyAdmin. Due to the limitation in URL matching, it was possible to bypass the URL white-list protection. All 4.6.x versions (prior to 4.6.5), 4.4.x versions (prior to 4.4.15.9), and 4.0.x versions (prior to 4.0.10.18) are affected.
An issue was discovered in phpMyAdmin. Due to a bug in serialized string parsing, it was possible to bypass the protection offered by PMA_safeUnserialize() function. All 4.6.x versions (prior to 4.6.5), 4.4.x versions (prior to 4.4.15.9), and 4.0.x versions (prior to 4.0.10.18) are affected.
openstack-nova: network security group changes are not applied to running instances
OpenStack Compute (Nova) before 2014.2.4 (juno) and 2015.1.x before 2015.1.2 (kilo) do not properly apply security group changes, which allows remote attackers to bypass intended restriction by leveraging an instance that was running when the change was made.
GE Healthcare Discovery VH has a default password of (1) interfile for the ftpclient user of the Interfile server or (2) "2" for the LOCAL user of the FTP server for the Codonics printer, which has unspecified impact and attack vectors.
ZOLL Defibrillator / Monitor M Series, E Series, and R Series have a default password for System Configuration mode, which allows physically proximate attackers to modify device configuration and cause a denial of service (adverse human health effects).
GE Healthcare Centricity DMS 4.2, 4.1, and 4.0 has a password of Muse!Admin for the Museadmin user, which has unspecified impact and attack vectors. NOTE: it is not clear whether this password is default, hardcoded, or dependent on another system or product that requires a fixed value.
GE Healthcare Discovery 530C has a password of #bigguy1 for the (1) acqservice user and (2) wsservice user of the Xeleris System, which has unspecified impact and attack vectors. NOTE: it is not clear whether this password is default, hardcoded, or dependent on another system or product that requires a fixed value.
Arris DG860A, TG862A, and TG862G devices with firmware TS0703128_100611 through TS0705125D_031115 have predictable technician passwords, which makes it easier for remote attackers to obtain access via the web management interface, related to a "password of the day" issue.
GE Healthcare Optima CT680, CT540, CT640, and CT520 has a default password of #bigguy for the root user, which has unspecified impact and attack vectors.
The HIPAA configuration interface in GE Healthcare Optima MR360 has a password of (1) operator for the root account, (2) adw2.0 for the admin account, and (3) adw2.0 for the sdc account, which has unspecified impact and attack vectors. NOTE: it is not clear whether these passwords are default, hardcoded, or dependent on another system or product that requires a fixed value.
GE Healthcare Optima MR360 does not require authentication for the HIPAA emergency login procedure, which allows physically proximate users to gain access via an arbitrary username in the Emergency Login screen. NOTE: this might not qualify for inclusion in CVE if unauthenticated emergency access is part of the intended security policy of the product, can be controlled by the system administrator, and is not enabled by default.
GE Healthcare CADStream Server has a default password of confirma for the admin user, which has unspecified impact and attack vectors.
The Acquisition Workstation for the GE Healthcare Revolution XQ/i has a password of adw3.1 for the sdc user, which has unspecified impact and attack vectors. NOTE: it is not clear whether this password is default, hardcoded, or dependent on another system or product that requires a fixed value.
The password-reset feature in as/index.php in SweetRice CMS before 0.6.7.1 allows remote attackers to modify the administrator's password by specifying the administrator's e-mail address in the email parameter.
Domain Technologie Control (DTC) before 0.34.1 includes a password in the -b command line argument to htpasswd, which might allow local users to read the password by listing the process and its arguments.
Citrix NetScaler Application Delivery Controller (ADC) 9.3.x before 9.3-64.4, 10.0 before 10.0-77.5, and 10.1 before 10.1-118.7 logs user credentials, which allows attackers to obtain sensitive information via unspecified vectors.
Juvia uses the same secret key for all installations, which allows remote attackers to have unspecified impact by leveraging the secret key in app/config/initializers/secret_token.rb, related to cookies.
The forgotten-password feature in forcepasswd.do in the management GUI in Symantec LiveUpdate Administrator (LUA) 2.x before 2.3.2.110 allows remote attackers to reset arbitrary passwords by providing the e-mail address associated with a user account.