An issue was discovered in Elspec G5 digital fault recorder versions 1.1.4.15 and before. A hardcoded backdoor session ID exists that can be used for further access to the device, including reconfiguration tasks.
Search vulnerabilities
Fresenius Kabi Agilia Connect Infusion System
Sensitive endpoints in Fresenius Kabi Agilia Link+ v3.0 and prior can be accessed without any authentication information such as the session cookie. An attacker can send requests to sensitive endpoints as an unauthenticated user to perform critical actions or modify critical configuration parameters.
Fresenius Kabi Agilia Connect Infusion System hard coded credentials
Vigilant Software Suite (Mastermed Dashboard) version 2.0.1.3 contains service credentials likely to be common across all instances. An attacker in possession of the password may gain privileges on all installations of this software.
Advantech ADAM-3600
The affected product has a hardcoded private key available inside the project folder, which may allow an attacker to achieve Web Server login and perform further actions.
PTC Axeda agent and Axeda Desktop Server Use of Hard-Coded Credentials
Axeda agent (All versions) and Axeda Desktop Server for Windows (All versions) uses hard-coded credentials for its UltraVNC installation. Successful exploitation of this vulnerability could allow a remote authenticated attacker to take full remote control of the host operating system.
Rockwell Automation ISaGRAF5 Runtime Use of Hard-coded Cryptographic Key
Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x includes the functionality of setting a password that is required to execute privileged commands. The password value passed to ISaGRAF Runtime is the result of encryption performed with a fixed key value using the tiny encryption algorithm (TEA) on an entered or saved password. A remote, unauthenticated attacker could pass their own encrypted password to the ISaGRAF 5 Runtime, which may result in information disclosure on the device.
GE Reason RT43X Clocks Use of Hard-coded Cryptographic Key
By having access to the hard-coded cryptographic key for GE Reason RT430, RT431 & RT434 GNSS clocks in firmware versions prior to version 08A06, attackers would be able to intercept and decrypt encrypted traffic through an HTTPS connection.
B. Braun SpaceCom, Battery Pack SP with Wi-Fi, and Data module compactplus
Hard-coded credentials in the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 enable attackers with command line access to access the device’s Wi-Fi module.
KUKA KR C4 - Use of Hard-Coded Credentials
An attacker can gain full access (read/write/delete) to sensitive folders due to hard-coded credentials on KUKA KR C4 control software for versions prior to 8.7 or any product running KSS.
GE Voluson S8 Service Browser hard-coded credentials
A vulnerability was found in GE Voluson S8. It has been rated as critical. This issue affects the Service Browser which itroduces hard-coded credentials. Attacking locally is a requirement. It is recommended to change the configuration settings.
ICSA-22-200-01 MiCODUS MV720 GPS tracker Use of Hard-coded Credentials
The MiCODUS MV720 GPS tracker API server has an authentication mechanism that allows devices to use a hard-coded master password. This may allow an attacker to send SMS commands directly to the GPS tracker as if they were coming from the GPS owner’s mobile number.
Contec Health CMS8000
Multiple globally default credentials exist across all CMS8000 devices, that once exposed, allow a threat actor with momentary physical access to gain privileged access to any device. Privileged credential access enables the extraction of sensitive patient information or modification of device parameters
Delta Industrial Automation DIALink versions 1.4.0.0 and prior are vulnerable to the use of a hard-coded cryptographic key which could allow an attacker to decrypt sensitive data and compromise the machine.
An information disclosure vulnerability exists due to the hardcoded TLS key of reolink RLC-410W v3.0.0.136_20121102. A specially-crafted man-in-the-middle attack can lead to a disclosure of sensitive information. An attacker can perform a man-in-the-middle attack to trigger this vulnerability.
An authentication bypass vulnerability exists in the Web Application functionality of Moxa MXView Series 3.2.4. A specially-crafted HTTP request can lead to unauthorized access. An attacker can send an HTTP request to trigger this vulnerability.
An information disclosure vulnerability exists in the router configuration export functionality of InHand Networks InRouter302 V3.5.4. A specially-crafted network request can lead to increased privileges. An attacker can send an HTTP request to trigger this vulnerability.
A hard-coded password vulnerability exists in the console infactory functionality of InHand Networks InRouter302 V3.5.37. A specially-crafted network request can lead to privileged operation execution. An attacker can send a sequence of requests to trigger this vulnerability.
A hard-coded password vulnerability exists in the libcommonprod.so prod_change_root_passwd functionality of TCL LinkHub Mesh Wi-Fi MS1G_00_01.00_14. During system startup this functionality is always called, leading to a known root password. An attacker does not have to do anything to trigger this vulnerability.
A hard-coded password vulnerability exists in the telnet functionality of Abode Systems, Inc. iota All-In-One Security Kit 6.9Z. Use of a hard-coded root password can lead to arbitrary command execution. An attacker can authenticate with hard-coded credentials to trigger this vulnerability.
Telecommunication Software SAMwin Contact Center Suite Credential SAMwinLIBVB.dll getCurrentDBVersion hard-coded credentials
A vulnerability was found in Telecommunication Software SAMwin Contact Center Suite 5.1. It has been rated as critical. Affected by this issue is the function getCurrentDBVersion in the library SAMwinLIBVB.dll of the credential handler. Authentication is possible with hard-coded credentials. Upgrading to version 6.2 is able to address this issue. It is recommended to upgrade the affected component.