The Lenovo Service Framework Android application uses a set of nonsecure credentials when performing integrity verification of downloaded applications and/or data. This exposes the application to man-in-the-middle attacks leading to possible remote code execution.
Search vulnerabilities
VMware vCenter Server (6.5 prior to 6.5 U1) contains an information disclosure vulnerability. This issue may allow plaintext credentials to be obtained when using the vCenter Server Appliance file-based backup feature.
rabbitmq: Authentication details are stored in browser-local storage without expiration
An issue was discovered in these Pivotal RabbitMQ versions: all 3.4.x versions, all 3.5.x versions, and 3.6.x versions prior to 3.6.9; and these RabbitMQ for PCF versions: all 1.5.x versions, 1.6.x versions prior to 1.6.18, and 1.7.x versions prior to 1.7.15. RabbitMQ management UI stores signed-in user credentials in a browser's local storage without expiration, making it possible to retrieve them using a chained attack.
An issue was discovered in Honeywell XL Web II controller XL1000C500 XLWebExe-2-01-00 and prior, and XLWeb 500 XLWebExe-1-02-08 and prior. Any user is able to disclose a password by accessing a specific URL, because of Plaintext Storage of a Password.
An issue was discovered in Honeywell XL Web II controller XL1000C500 XLWebExe-2-01-00 and prior, and XLWeb 500 XLWebExe-1-02-08 and prior. Password is stored in clear text.
A Weak Cryptography for Passwords issue was discovered in General Electric (GE) Multilin SR 750 Feeder Protection Relay, firmware versions prior to Version 7.47; SR 760 Feeder Protection Relay, firmware versions prior to Version 7.47; SR 469 Motor Protection Relay, firmware versions prior to Version 5.23; SR 489 Generator Protection Relay, firmware versions prior to Version 4.06; SR 745 Transformer Protection Relay, firmware versions prior to Version 5.23; SR 369 Motor Protection Relay, all firmware versions; Multilin Universal Relay, firmware Version 6.0 and prior versions; and Multilin URplus (D90, C90, B95), all versions. Ciphertext versions of user passwords were created with a non-random initialization vector leaving them susceptible to dictionary attacks. Ciphertext of user passwords can be obtained from the front LCD panel of affected products and through issued Modbus commands.
A Password in Configuration File issue was discovered in Dahua DH-IPC-HDBW23A0RN-ZS, DH-IPC-HDBW13A0SN, DH-IPC-HDW1XXX, DH-IPC-HDW2XXX, DH-IPC-HDW4XXX, DH-IPC-HFW1XXX, DH-IPC-HFW2XXX, DH-IPC-HFW4XXX, DH-SD6CXX, DH-NVR1XXX, DH-HCVR4XXX, DH-HCVR5XXX, DHI-HCVR51A04HE-S3, DHI-HCVR51A08HE-S3, and DHI-HCVR58A32S-S2 devices. The password in configuration file vulnerability was identified, which could lead to a malicious user assuming the identity of a privileged user and gaining access to sensitive information.
Wireless IP Camera (P2P) WIFICAM devices have an "Apple Production IOS Push Services" private RSA key and certificate stored in /system/www/pem/ck.pem inside the firmware, which allows attackers to obtain sensitive information.
On Wireless IP Camera (P2P) WIFICAM devices, access to .ini files (containing credentials) is not correctly checked. An attacker can bypass authentication by providing an empty loginuse parameter and an empty loginpas parameter in the URI.
kedpm 0.5 and 1.0 creates a history file in ~/.kedpm/history that is written in cleartext. All of the commands performed in the password manager are written there. This can lead to the disclosure of the master password if the "password" command is used with an argument. The names of the password entries created and consulted are also accessible in cleartext.
Schneider Electric StruxureWare Data Center Expert before 7.4.0 uses cleartext RAM storage for passwords, which might allow remote attackers to obtain sensitive information via unspecified vectors.
Cleartext password storage exists on Peplink Balance 305, 380, 580, 710, 1350, and 2500 devices with firmware before fw-b305hw2_380hw6_580hw2_710hw3_1350hw2_2500-7.0.1-build2093. The files in question are /etc/waipass and /etc/roapass. In case one of these devices is compromised, the attacker can gain access to passwords and abuse them to compromise further systems.
An issue was discovered on Mimosa Client Radios before 2.2.3. In the device's web interface, there is a page that allows an attacker to use an unsanitized GET parameter to download files from the device as the root user. The attacker can download any file from the device's filesystem. This can be used to view unsalted, MD5-hashed administrator passwords, which can then be cracked, giving the attacker full admin access to the device's web interface. This vulnerability can also be used to view the plaintext pre-shared key (PSK) for encrypted wireless connections, or to view the device's serial number (which allows an attacker to factory reset the device).
Ovarro TBox Insufficiently Protected Credentials
An attacker can decrypt the Ovarro TBox login password by communication capture and brute force attacks.
Pentaminds CuroVMS v2.0.1 was discovered to contain exposed credentials.
Rockwell Automation ISaGRAF5 Runtime Unprotected Storage of Credentials
Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x stores the password in plaintext in a file that is in the same directory as the executable file. ISaGRAF Runtime reads the file and saves the data in a variable without any additional modification. A local, unauthenticated attacker could compromise the user passwords, resulting in information disclosure.
Fresenius Kabi Agilia Connect Infusion System insufficiently protected credentials
The web application on Agilia Link+ version 3.0 implements authentication and session management mechanisms exclusively on the client-side and does not protect authentication attributes sufficiently.
Fresenius Kabi Agilia Connect Infusion System plaintext storage of a password
An attacker with physical access to the host can extract the secrets from the registry and create valid JWT tokens for the Fresenius Kabi Vigilant MasterMed version 2.0.1.3 application and impersonate arbitrary users. An attacker could manipulate RabbitMQ queues and messages by impersonating users.
Philips Vue PACS Insufficiently Protected Credentials
Philips Vue PACS versions 12.2.x.x and prior transmits or stores authentication credentials, but it uses an insecure method susceptible to unauthorized interception and/or retrieval.
Automation Direct CLICK PLC CPU Modules Plaintext Storage of a Password
The programming protocol allows for a previously entered password and lock state to be read by an attacker. If the previously entered password was successful, the attacker can then use the password to unlock Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00.