A authentication bypass using an alternate path or channel in Fortinet FortiClientWindows version 7.4.0, versions 7.2.4 through 7.2.0, versions 7.0.12 through 7.0.0, and 6.4.10 through 6.4.0 allows low privilege attacker to execute arbitrary code with high privilege via spoofed named pipe messages.
Export limit exceeded: 10090 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search vulnerabilities
An improper authorization vulnerability [CWE-285] in FortiSOAR version 7.4.0 through 7.4.3, 7.3.0 through 7.3.2, 7.2.0 through 7.2.2, 7.0.0 through 7.0.3 change password endpoint may allow an authenticated attacker to perform a brute force attack on users and administrators password via crafted HTTP requests.
A relative path traversal vulnerability (CWE-23) in FortiWAN version 4.5.7 and below, 4.4 all versions may allow a remote non-authenticated attacker to delete files on the system by sending a crafted POST request. In particular, deleting specific configuration files will reset the Admin password to its default value.
Authentication Bypass Vulnerability in Hitachi Ops Center Common Services
Authentication Bypass vulnerability in Hitachi Ops Center Common Services.This issue affects Hitachi Ops Center Common Services: from 10.9.3-00 before 11.0.2-01.
CVE-2022-46732
Even if the authentication fails for local service authentication, the requested command could still execute regardless of authentication status.
An authentication bypass in the admin web console of Ivanti CSA before 5.0.3 allows a remote unauthenticated attacker to gain administrative access
Missing Authentication for critical function vulnerability in HYPR Server allows Authentication Bypass when using Legacy APIs.This issue affects HYPR Server: before 8.0 (with enabled Legacy APIs)
SAUTER Controls Nova 200–220 Series Missing Authentication for Critical Function
SAUTER Controls Nova 200–220 Series with firmware version 3.3-006 and prior and BACnetstac version 4.2.1 and prior allows the execution of commands without credentials. As Telnet and file transfer protocol (FTP) are the only protocols available for device management, an unauthorized user could access the system and modify the device configuration, which could result in the unauthorized user executing unrestricted malicious commands.
Snap One Wattbox WB-300-IP-3 versions WB10.9a17 and prior could bypass the brute force protection, allowing multiple attempts to force a login.
CVE-2023-0102
LS ELECTRIC XBC-DN32U with operating system version 01.80 is missing authentication for its deletion command. This could allow an attacker to delete arbitrary files.
CVE-2023-22803
LS ELECTRIC XBC-DN32U with operating system version 01.80 is missing authentication to perform critical functions to the PLC. This could allow an attacker to change the PLC's mode arbitrarily.
CVE-2023-22804
LS ELECTRIC XBC-DN32U with operating system version 01.80 is missing authentication to create users on the PLC. This could allow an attacker to create and use an account with elevated privileges and take control of the device.
CVE-2023-1140
Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a vulnerability that could allow an attacker to achieve unauthenticated remote code execution in the context of an administrator.
Dover Fueling Solutions MAGLINK LX Web Console Authentication Bypass by Primary Weakness
Dover Fueling Solutions MAGLINK LX Web Console Configuration versions 2.5.1, 2.5.2, 2.5.3, 2.6.1, 2.11, 3.0, 3.2, and 3.3 could allow a guest user to elevate to admin privileges.
Sielco Radio Link and Analog FM Transmitters Improper Access Control
The cookie session ID is of insufficient length and can be exploited by brute force, which may allow a remote attacker to obtain a valid session, bypass authentication, and manipulate the transmitter.
Improper Restriction of Excessive Authentication Attempts in Sielco PolyEco1000
Sielco PolyEco1000 uses a weak set of default administrative credentials that can be easily guessed in remote password attacks and gain full control of the system.
Nextcloud user_oidc app is missing brute force protection
user_oidc app is an OpenID Connect user backend for Nextcloud. Authentication can be broken/bypassed in user_oidc app. It is recommended that the Nextcloud user_oidc app is upgraded to 1.3.2
MantisBT user account takeover in the signup/reset password process
MantisBT (Mantis Bug Tracker) is an open source issue tracker. Insufficient access control in the registration and password reset process allows an attacker to reset another user's password and takeover their account, if the victim has an incomplete request pending. The exploit is only possible while the verification token is valid, i.e for 5 minutes after the confirmation URL sent by e-mail has been opened, and the user did not complete the process by updating their password. A brute-force attack calling account_update.php with increasing user IDs is possible. A successful takeover would grant the attacker full access to the compromised account, including sensitive information and functionalities associated with the account, the extent of which depends on its privileges and the data it has access to. Version 2.26.2 contains a patch for the issue. As a workaround, one may mitigate the risk by reducing the verification token's validity (change the value of the `TOKEN_EXPIRY_AUTHENTICATED` constant in `constants_inc.php`).
Talend Data Catalog remote harvesting server before 8.0-20230413 contains a /upgrade endpoint that allows an unauthenticated WAR file to be deployed on the server. (A mitigation is that the remote harvesting server should be behind a firewall that only allows access to the Talend Data Catalog server.)
The hwPartsDFR module has a vulnerability in API calling verification. Successful exploitation of this vulnerability may affect device confidentiality.