A vulnerability has been identified in SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 V17 (All versions < V17 Update 9), SIMATIC STEP 7 V18 (All versions < V18 Update 6), SIMATIC STEP 7 V19 (All versions < V19 Update 4), SIMATIC STEP 7 V20 (All versions < V20 Update 4), SIMATIC WinCC V17 (All versions < V17 Update 9), SIMATIC WinCC V18 (All versions < V18 Update 6), SIMATIC WinCC V19 (All versions < V19 Update 4), SIMATIC WinCC V20 (All versions < V20 Update 4), SIMOCODE ES V17 (All versions), SIMOCODE ES V18 (All versions), SIMOCODE ES V19 (All versions), SIMOCODE ES V20 (All versions), SIMOTION SCOUT TIA V5.4 (All versions), SIMOTION SCOUT TIA V5.5 (All versions), SIMOTION SCOUT TIA V5.6 (All versions < V5.6 SP1 HF7), SIMOTION SCOUT TIA V5.7 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SINAMICS Startdrive V19 (All versions), SINAMICS Startdrive V20 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions), SIRIUS Safety ES V18 (TIA Portal) (All versions), SIRIUS Safety ES V19 (TIA Portal) (All versions), SIRIUS Safety ES V20 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V19 (TIA Portal) (All versions), SIRIUS Soft Starter ES V20 (TIA Portal) (All versions), TIA Portal Cloud V17 (All versions < V6.0.0.0), TIA Portal Cloud V18 (All versions < V6.3.0.2), TIA Portal Cloud V19 (All versions < V5.2.1.1), TIA Portal Cloud V20 (All versions < V5.2.2.2). Affected products do not properly sanitize stored security properties when parsing project files. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application.
Search vulnerabilities
A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V11.0), SIPROTEC 5 6MD85 (CP300) (All versions < V11.0), SIPROTEC 5 6MD86 (CP300) (All versions < V11.0), SIPROTEC 5 6MD89 (CP300) (All versions < V11.0), SIPROTEC 5 6MD89 (CP300) V9.6x (All versions < V11.0), SIPROTEC 5 6MU85 (CP300) (All versions < V11.0), SIPROTEC 5 7KE85 (CP300) (All versions < V11.0), SIPROTEC 5 7SA82 (CP100) (All versions < V8.91), SIPROTEC 5 7SA82 (CP150) (All versions < V11.0), SIPROTEC 5 7SA86 (CP300) (All versions < V11.0), SIPROTEC 5 7SA87 (CP300) (All versions < V11.0), SIPROTEC 5 7SD82 (CP100) (All versions < V8.91), SIPROTEC 5 7SD82 (CP150) (All versions < V11.0), SIPROTEC 5 7SD86 (CP300) (All versions < V11.0), SIPROTEC 5 7SD87 (CP300) (All versions < V11.0), SIPROTEC 5 7SJ81 (CP100) (All versions < V8.91), SIPROTEC 5 7SJ81 (CP150) (All versions < V11.0), SIPROTEC 5 7SJ82 (CP100) (All versions < V8.91), SIPROTEC 5 7SJ82 (CP150) (All versions < V11.0), SIPROTEC 5 7SJ85 (CP300) (All versions < V11.0), SIPROTEC 5 7SJ86 (CP300) (All versions < V11.0), SIPROTEC 5 7SK82 (CP100) (All versions < V8.91), SIPROTEC 5 7SK82 (CP150) (All versions < V11.0), SIPROTEC 5 7SK85 (CP300) (All versions < V11.0), SIPROTEC 5 7SL82 (CP100) (All versions < V8.91), SIPROTEC 5 7SL82 (CP150) (All versions < V11.0), SIPROTEC 5 7SL86 (CP300) (All versions < V11.0), SIPROTEC 5 7SL87 (CP300) (All versions < V11.0), SIPROTEC 5 7SS85 (CP300) (All versions < V11.0), SIPROTEC 5 7ST85 (CP300) (All versions < V11.0), SIPROTEC 5 7ST86 (CP300) (All versions < V11.0), SIPROTEC 5 7SX82 (CP150) (All versions < V11.0), SIPROTEC 5 7SX85 (CP300) (All versions < V11.0), SIPROTEC 5 7SY82 (CP150) (All versions < V11.0), SIPROTEC 5 7UM85 (CP300) (All versions < V11.0), SIPROTEC 5 7UT82 (CP100) (All versions < V8.91), SIPROTEC 5 7UT82 (CP150) (All versions < V11.0), SIPROTEC 5 7UT85 (CP300) (All versions < V11.0), SIPROTEC 5 7UT86 (CP300) (All versions < V11.0), SIPROTEC 5 7UT87 (CP300) (All versions < V11.0), SIPROTEC 5 7VE85 (CP300) (All versions < V11.0), SIPROTEC 5 7VK87 (CP300) (All versions < V11.0), SIPROTEC 5 7VU85 (CP300) (All versions < V11.0), SIPROTEC 5 Compact 7SX800 (CP050) (All versions < V11.0). The affected devices include session identifiers in URL requests for certain functionalities. This could allow an attacker to retrieve sensitive session data from browser history, logs, or other storage mechanisms, potentially leading to unauthorized access.
A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SIMATIC PCS neo V6.0 (All versions < V6.0 SP1 Update 1), SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 V17 (All versions < V17 Update 9), SIMATIC STEP 7 V18 (All versions < V18 Update 6), SIMATIC STEP 7 V19 (All versions < V19 Update 4), SIMATIC STEP 7 V20 (All versions < V20 Update 4), SIMATIC WinCC V17 (All versions < V17 Update 9), SIMATIC WinCC V18 (All versions < V18 Update 6), SIMATIC WinCC V19 (All versions < V19 Update 4), SIMATIC WinCC V20 (All versions < V20 Update 4), SIMOCODE ES V17 (All versions), SIMOCODE ES V18 (All versions), SIMOCODE ES V19 (All versions), SIMOCODE ES V20 (All versions), SIMOTION SCOUT TIA V5.4 (All versions < V17 Update 9), SIMOTION SCOUT TIA V5.5 (All versions < V18 Update 6), SIMOTION SCOUT TIA V5.6 (All versions < V19 Update 4), SIMOTION SCOUT TIA V5.7 (All versions < V20 Update 4), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SINAMICS Startdrive V19 (All versions), SINAMICS Startdrive V20 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions), SIRIUS Safety ES V18 (TIA Portal) (All versions), SIRIUS Safety ES V19 (TIA Portal) (All versions), SIRIUS Safety ES V20 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V19 (TIA Portal) (All versions), SIRIUS Soft Starter ES V20 (TIA Portal) (All versions), TIA Portal Cloud V17 (All versions < V6.0.0.0), TIA Portal Cloud V18 (All versions < V6.3.0.2), TIA Portal Cloud V19 (All versions < V5.2.1.1), TIA Portal Cloud V20 (All versions < V5.2.2.2), TIA Portal Test Suite V20 (All versions < V20 Update 4). Affected products do not properly sanitize Interprocess Communication input received through a Windows Named Pipe accessible to all local users. This could allow an authenticated local attacker to cause a type confusion and execute arbitrary code within the affected application.
A vulnerability has been identified in SIMATIC S7-PLCSIM V16 (All versions), SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 Safety V16 (All versions), SIMATIC STEP 7 Safety V17 (All versions < V17 Update 9), SIMATIC STEP 7 Safety V18 (All versions < V18 Update 6), SIMATIC STEP 7 Safety V19 (All versions < V19 Update 4), SIMATIC STEP 7 V16 (All versions), SIMATIC STEP 7 V17 (All versions < V17 Update 9), SIMATIC STEP 7 V18 (All versions < V18 Update 6), SIMATIC STEP 7 V19 (All versions < V19 Update 4), SIMATIC WinCC Unified V16 (All versions), SIMATIC WinCC Unified V17 (All versions < V17 Update 9), SIMATIC WinCC Unified V18 (All versions < V18 Update 6), SIMATIC WinCC Unified V19 (All versions < V19 Update 4), SIMATIC WinCC V16 (All versions), SIMATIC WinCC V17 (All versions < V17 Update 9), SIMATIC WinCC V18 (All versions < V18 Update 6), SIMATIC WinCC V19 (All versions < V19 Update 4), SIMOCODE ES V16 (All versions), SIMOCODE ES V17 (All versions), SIMOCODE ES V18 (All versions), SIMOCODE ES V19 (All versions), SIMOTION SCOUT TIA V5.4 (All versions < V17 Update 9), SIMOTION SCOUT TIA V5.5 (All versions < V18 Update 6), SIMOTION SCOUT TIA V5.6 (All versions < V19 Update 4), SINAMICS Startdrive V16 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SINAMICS Startdrive V19 (All versions), SIRIUS Safety ES V17 (TIA Portal) (All versions), SIRIUS Safety ES V18 (TIA Portal) (All versions < V18 Update 6), SIRIUS Safety ES V19 (TIA Portal) (All versions), SIRIUS Soft Starter ES V17 (TIA Portal) (All versions), SIRIUS Soft Starter ES V18 (TIA Portal) (All versions), SIRIUS Soft Starter ES V19 (TIA Portal) (All versions), TIA Portal Cloud V16 (All versions), TIA Portal Cloud V17 (All versions < V6.0.0.0), TIA Portal Cloud V18 (All versions < V6.3.0.2), TIA Portal Cloud V19 (All versions < V5.2.1.1). Affected products do not properly sanitize user-controllable input when parsing log files. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application.
BookingPress <= 1.1.28 - Unauthenticated PHP Object Injection
The Appointment Booking Calendar Plugin and Scheduling Plugin WordPress plugin through 1.1.28 does not validate data before passing it to a PHP deserialization function, allowing unauthenticated attackers to inject arbitrary PHP objects; where a suitable gadget chain is present on the site this can be leveraged to achieve remote code execution.
Everest Forms < 3.5.0 - Unauthenticated Sensitive Information Exposure via Residual CSV Artifacts
The Everest Forms WordPress plugin before 3.5.0 does not reliably delete temporary CSV files generated during email-notification processing and leaves them publicly accessible in the uploads directory, allowing unauthenticated attackers to retrieve other users' form submission records via predictable, enumerable filenames.
WordPress Real Testimonials plugin <= 3.1.15 - PHP Object Injection vulnerability
Deserialization of Untrusted Data vulnerability in ShapedPlugin LLC Real Testimonials testimonial-free allows Object Injection.This issue affects Real Testimonials: from n/a through <= 3.1.15.
Newsletters < 4.15 - Unauthenticated PHP Object Injection via Subscriber Custom Field
The Newsletters WordPress plugin before 4.15 does not prevent deserialization of untrusted input that is stored through a public form, allowing unauthenticated attackers to inject a PHP object and, via a property-oriented gadget chain bundled with the Newsletters WordPress plugin before 4.15, write arbitrary files and execute code on the server.
Paid Member Subscriptions < 3.0.7 - Unauthenticated Sensitive Information Exposure via Residual Export Files
The Paid Membership Subscriptions WordPress plugin before 3.0.7 does not protect the member and payment export files it writes to a predictable location in the uploads directory, allowing unauthenticated users to download the exported member and payment data (including PII) while an export artifact is present.
Kirki < 6.0.13 - Unauthenticated PHP Object Injection
The Kirki WordPress plugin before 6.0.13 does not restrict which classes may be instantiated when it deserialises data that unauthenticated users can store, leading to PHP Object Injection that is triggered when an administrator later reviews the stored data. With a suitable gadget chain present on the site (via another installed Kirki WordPress plugin before 6.0.13, , or an outdated WordPress version), this could be leveraged to perform a variety of attacks, such as remote code execution.
Hardcoded AES Key Enables Credential Disclosure
The LaserGest mobile application encrypts stored assistance portal credentials with a hardcoded AES key and IV, allowing an attacker with access to the application package to recover them in cleartext.
compose-lint: A committed symlink makes compose-lint quote a file from outside the project into its output
compose-lint is a Docker Compose security linter that identifies dangerous misconfigurations before deployment. From 0.2.0 until 0.25.0, compose-lint follows a project-controlled symbolic link used as the Compose file outside the project. The same issue affects compose.override.yml and a COMPOSE_FILE entry from 0.22.0, and an env_file target from 0.23.0. If an external Compose-related target fails YAML parsing, the error quotes an attacker-uncontrolled line into standard error, JSON errors, and SARIF notifications, while an external env_file can expose credential-like key names through CL-0020 and CL-0021 findings. The attacker selects the target path but not the exact parser-failure line, values from env_file are not printed, and the pass or fail result is unchanged. This issue is fixed in version 0.25.0.
.NET Remote Code Execution Vulnerability
Deserialization of untrusted data in .NET allows an unauthorized attacker to execute code over a network.
.NET Framework Remote Code Execution Vulnerability
Deserialization of untrusted data in .NET Framework allows an unauthorized attacker to execute code over a network.
.NET Elevation of Privilege Vulnerability
Improper link resolution before file access ('link following') in .NET allows an authorized attacker to elevate privileges locally.
.NET Elevation of Privilege Vulnerability
Improper link resolution before file access ('link following') in .NET allows an authorized attacker to elevate privileges locally.
e107: Unsafe deserialization in install.php allows unauthenticated RCE via POP chain
e107 is a content management system (CMS). Prior to 2.3.7, install.php decodes the attacker-controlled previous_steps POST parameter and passes it to unserialize() at file scope and again in the e_install constructor without restricting allowed classes. The installer remains accessible after a normal installation, and a crafted object graph using the bundled GuzzleHttp\Psr7\PumpStream class can flow through paths.hash into site_path, where string coercion invokes an attacker-controlled callable. An unauthenticated attacker who can reach install.php can therefore execute arbitrary PHP functions with the web server process's privileges, leading to full server compromise. This issue is fixed in version 2.3.7.
Unauthenticated SSRF with MNESTIX_BACKEND_API_KEY disclosure in Eclipse Mnestix Browser server actions for configured Infrastructures
In Eclipse Mnestix Browser versions 1.6.0 up until but excluding 2.3.0 it was possible for an unauthenticated attacker to exfiltrate the MNESTIX_BACKEND_API_KEY for all configured Infrastructures.
Kubeflow Pipelines: Cross-tenant execution-cache poisoning / output substitution via a namespace-blind cache key in the cache webhook (multi-user)
Kubeflow Pipelines enables users to build and deploy portable, scalable machine learning workflows. Prior to 2.18.0, the legacy V1/raw-Argo execution cache mutating webhook and cache-server storage path hash selected template fields without the Kubernetes namespace, use the key alone for lookups and duplicate checks, and trust the mutable pipelines.kubeflow.org/execution_cache_key annotation when publishing outputs. In multi-user deployments where tenant namespaces share the cache service, a tenant with workload-submission privileges can read another namespace's cached outputs or seed matching outputs that are substituted into a later step. Standard KFP V2 component pods bypass this cache, matching requires the selected template fields and staleness policy, and arbitrary code execution or service availability impact is not established. This issue is fixed in version 2.18.0.
jackson-databind: PolymorphicTypeValidator bypass via generic type arguments and array element types allows arbitrary class instantiation (incomplete fix for CVE-2026-54512)
jackson-databind validates the outer class of a class-name type ID but accepts attacker-selected classes inside its generic arguments, even when those classes violate the declared type or would be rejected as direct type IDs. This bypasses the generic-argument validation added for CVE-2026-54512 (GHSA-j3rv-43j4-c7qm), of which this is an incomplete fix. DatabindContext._resolveAndValidateGeneric() checks the outer class against the declared base type and then passes each argument from the type ID to _validateTypeParameter(), which validates the argument against the outer base type rather than enforcing its corresponding declared generic binding. It also invokes validators with arguments that have not passed the subtype check those validators expect. Under the default DefaultBaseTypeLimitingValidator this accepts an unrelated class inside a generic subtype even when the same class is rejected as a direct type ID. Where an allowIfBaseType(...) rule approves the outer type, Jackson substitutes LaissezFaireSubTypeValidator, so the configured validator no longer restricts the embedded arguments. The element type of a plain array type ID such as [Lpkg.Gadget; is likewise left unvalidated once the array's base type is approved. Affected paths include annotation-based class-name polymorphism with a default Jackson 3.x JsonMapper, configured default typing in both Jackson 2.x and 3.x, and integrations that expose that default typing. The default-validator case requires no application-authored validator: with @JsonTypeInfo(use = Id.CLASS), a direct gadget type ID is rejected as "Not a subtype", while a type ID naming a generic wrapper around the same gadget is accepted and deserialized, including attacker-supplied bean properties. Where class-name default typing permits Map, a property declared as Map<String,String> accepts HashMap<FileSystemXmlApplicationContext,String>; map-key discovery then passes the attacker-controlled JSON property name to the selected class's one-string constructor. With Spring on the classpath and attacker-controlled XML the application can load, that constructor loads the XML and invokes ProcessBuilder.start() under the application account, giving arbitrary command execution. This issue affects com.fasterxml.jackson.core:jackson-databind from 2.10.0 and tools.jackson.core:jackson-databind from 3.0.0. Releases before 2.10.0 are not affected, because PolymorphicTypeValidator was introduced in jackson-databind 2.10.0.