Information Disclosure can occur in encryptionProfiles.jsd in Hitek Software's Automize because of the Read attribute being set for Users. This allows an attacker to recover encrypted passwords for GPG Encryption profiles. Verified in all 10.x versions up to and including 10.25, and all 11.x versions up to and including 11.14.
Search vulnerabilities
An issue was discovered in the software on Vaultek Gun Safe VT20i products. There is no encryption of the session between the Android application and the safe. The website and marketing materials advertise that this communication channel is encrypted with "Highest Level Bluetooth Encryption" and "Data transmissions are secure via AES256 bit encryption." These claims, however, are not true. Moreover, AES256 bit encryption is not supported in the Bluetooth Low Energy (BLE) standard, so it would have to be at the application level. This lack of encryption allows an individual to learn the passcode by eavesdropping on the communications between the application and the safe.
Due to a lack of standard encryption when transmitting sensitive information over the internet to a centralized monitoring service, the Eview EV-07S GPS Tracker discloses personally identifying information, such as GPS data and IMEI numbers, to any man-in-the-middle (MitM) listener.
xbcrypt in Percona XtraBackup before 2.3.6 and 2.4.x before 2.4.5 does not properly set the initialization vector (IV) for encryption, which makes it easier for context-dependent attackers to obtain sensitive information from encrypted backup files via a Chosen-Plaintext attack. NOTE: this vulnerability exists because of an incomplete fix for CVE-2013-6394.
A vulnerability in Trend Micro ScanMail for Exchange 12.0 exists in which some communications to the update servers are not encrypted.
On Samsung NVR devices, remote attackers can read the MD5 password hash of the 'admin' account via certain szUserName JSON data to cgi-bin/main-cgi, and login to the device with that hash in the szUserPasswd parameter.
Lack of Transport Encryption in the public API in Philips Hue Bridge BSB002 SW 1707040932 allows remote attackers to read API keys (and consequently bypass the pushlink protection mechanism, and obtain complete control of the connected accessories) by leveraging the ability to sniff HTTP traffic on the local intranet network.
An Inadequate Encryption Strength issue was discovered in Mirion Technologies DMC 3000 Transmitter Module, iPam Transmitter f/DMC 2000, RDS-31 iTX and variants (including RSD31-AM Package), DRM-1/2 and variants (including Solar PWR Package), DRM and RDS Based Boundary Monitors, External Transmitters, Telepole II, and MESH Repeater (Telemetry Enabled Devices). Decryption of data is possible at the hardware level.
The DeskLock tool provided with FactoryTalk View SE uses a weak encryption algorithm that may allow a local, authenticated attacker to decipher user credentials, including the Windows user or Windows DeskLock passwords. If the compromised user has an administrative account, an attacker could gain full access to the user’s operating system and certain components of FactoryTalk View SE.
HCL BigFix Platform is affected by insecure credential storage
In specific scenarios, on Windows the operator credentials may be encrypted in a manner that is not completely machine-dependent.
Airspan Networks Mimosa Use of a Broken or Risky Cryptographic Algorithm
MMP: All versions prior to v1.0.3, PTP C-series: Device versions prior to v2.8.6.1, and PTMP C-series and A5x: Device versions prior to v2.5.4.1 uses the MD5 algorithm to hash the passwords before storing them but does not salt the hash. As a result, attackers may be able to crack the hashed passwords.
ICSA-20-140-02 Emerson OpenEnterprise
Inadequate encryption may allow the passwords for Emerson OpenEnterprise versions through 3.3.4 user accounts to be obtained.
MDT AutoSave Inadequate Encryption Strength
An attacker could decipher the encryption and gain access to MDT AutoSave versions prior to v6.02.06.
Emerson OpenEnterprise - Inadequate Encryption Strength
Inadequate encryption may allow the credentials used by Emerson OpenEnterprise, up through version 3.3.5, to access field devices and external systems to be obtained.
Update
Passwords are not adequately encrypted during the communication process between all versions of LS Industrial Systems (LSIS) Co. Ltd LS Electric XG5000 software prior to V4.0 and LS Electric PLCs: all versions of XGK-CPUU/H/A/S/E prior to V3.50, all versions of XGI-CPUU/UD/H/S/E prior to V3.20, all versions of XGR-CPUH prior to V1.80, all versions of XGB-XBMS prior to V3.00, all versions of XGB-XBCH prior to V1.90, and all versions of XGB-XECH prior to V1.30. This would allow an attacker to identify and decrypt the password of the affected PLCs by sniffing the PLC’s communication traffic.
The Config-files of Horner Automation’s RCC 972 with firmware version 15.40 are encrypted with weak XOR encryption vulnerable to reverse engineering. This could allow an attacker to obtain credentials to run services such as File Transfer Protocol (FTP) and Hypertext Transfer Protocol (HTTP).
IO FinNet tss-lib before 2.0.0 allows a collision of hash values.
Moxa MGate MB3180 before 1.8, MGate MB3280 before 2.7, MGate MB3480 before 2.6, MGate MB3170 before 2.5, and MGate MB3270 before 2.7 use weak encryption, which allows remote attackers to bypass authentication via a brute-force series of guesses for a parameter value.
openssl: SSL/TLS MITM vulnerability
OpenSSL before 0.9.8za, 1.0.0 before 1.0.0m, and 1.0.1 before 1.0.1h does not properly restrict processing of ChangeCipherSpec messages, which allows man-in-the-middle attackers to trigger use of a zero-length master key in certain OpenSSL-to-OpenSSL communications, and consequently hijack sessions or obtain sensitive information, via a crafted TLS handshake, aka the "CCS Injection" vulnerability.
Huawei AR routers with software before V200R007C00SPC100; Quidway S9300 routers with software before V200R009C00; S12700 routers with software before V200R008C00SPC500; S9300, Quidway S5300, and S5300 routers with software before V200R007C00; and S5700 routers with software before V200R007C00SPC500 make it easier for remote authenticated administrators to obtain and decrypt passwords by leveraging selection of a reversible encryption algorithm.